SP-3000 PLUS
- Ideal for Biochemical,Analytical, Agricultural and Medical Research
- Split-beam Optics, Dual detectors
- 1.0nm Bandwidth
- Sipper System
- PC interface Windows Program
Specification
Wavelength Range | 190nm~1100nm |
Spectral Bandwidth | 1.0nm |
Wavelength Display | Readable to 0.1nm |
Wavelength Accuracy | ±0.5nm(with automatic wavelength correction) |
Data Bunching Interval | 1nm |
Wavelength Reproducibility | ± 0.1nm |
Stray Light | Less than 0.05% (at 220nm and 340nm) |
Photometric Range | Absorbance: 00.3~3.0Abs |
Photometric System | Split-beam Optics, Dual detectors |
Photometric Accuracy | ±0.002Abs. at 0.5Abs. ±0.005Abs. at 1Abs |
Photometric Reproducibility | ±0.002Abs at 1.0Abs. |
Baseline Correction | Automatic |
Wavelength Slew Rate | About 5000nm/min |
Light Source | 6V 10W Tungsten halogen lamp and D2 lamp |
Monochromator | Modified Czerny-turmer type with 1200 limes/mm holographic grating. |
Auto Zero Function | By a single stroke of Soft key |
Display Graphic | LCD 6″, adjustable viewing angle and contrast control |
Detector | silicon photo-diode |
Sample Compartment | Automatically rotative 8 position cell holder |
Interface Ports | RS-232C and Centronics ports |
Power Requirements | 220-240VAC, 50/60Hz |
Dimensions | 514(W) x 243(H) x 430(D) mm |
Net Weight | 16.0kg |
Various applications and utilities
Correction Mode
Self correction for wavelength and cell holder position. Measured value for wavelength and cell holder position is compared with input correction data and then saved automatically.Self diagnosis
By checking lamp and wavelength correction condition, get a more reliable data. By testing intensity of radiation at specific wavelength in ultraviolet and visible range, can confirm its condition is good or not.
Lamp Change Mode
Setup the wavelength for changing point between deuterium lamp and tungsten-halogen lamp in range in range 350nm to 470nm for measuring with the optimum intensity of radiation.ABS/% T/CONC
Absorbance/transmittance/Concentration Measurement mode. Measuring one to ten samples for multi wavelength at a time. Saving measured method (Max 10). Concentration calculation with a standard curve or factor (Y=A*X+B; slope, B; intercept).
Survey Scan
Measure continuously absorbance/transmittance in 190nm~1100nm and confirm the data by Zoom in/out graphs in specific range. Search for Peaks and Valleys values automatically.Standard Curve
Can measure by 7 Standard samples at a time and select one of 13 kinds concentration unit, Linear(N), Linear(O), Segmented Standard curve Types. Also can Make Standard Curve by inputting the maximum 30 of Concentration and Absorbance.
ABS Ratio
Can measure DNA/Protein by Numerator, Denominator, Reference measurement and factor. 260, 280, 230nm and correction wavelength(320nm) are setup basically to measure more easily.
Simple Kinetics
Measure continuously absorbance/transmittance variation at one wavelength during a certain period. Measuring interval is over 0.1 second and total measuring time is 99 hours in a maximum.